Thomson Standard|Filter Vial – Thomson | Solutions At Work Thomson Standard Filter Vials can be used for samples containing less than 10% solid particulates. The filter vial consists of two p...


Description

Thomson Standard|Filter Vial - Thomson | Solutions At Work

Thomson Standard Filter Vials can be used for samples containing less than 10% solid particulates. The filter vial consists of two parts: a filter vial shell and a plunger which includes a single layer filter on one end and a vial cap on the other end. Applications for Standard Filter Vials include filtration of catalysts from organic and medicinal chemistry synthesis reactions, saccharide analysis in corn syrup, and in-vial protein precipitation.

Filter Vial Overview - Thomson | Solutions At Work

Syringe Filter: Syringe: Hplc Vial: HPLC Cap: Spin Filters: High Recovery Vials: HPLC Inserts: Fill & Dead Volume: Fill: 450μL / Dead:120μL: Fill: 630μL / Dead:420μL: Fill: 250μL / Dead:10μL: Pre Filtration: Particulate-Laden Samples: Solids or Large Particulates: High solid/liquid ratio: Minimize Matrix Effects & Ion Suppression: Allows for QuEChERS

Thomson SINGLE StEP Standard Filter Vials

Easy-to-use vials offer fast sample filtration and require only a squeeze of your fingers. Minimize sample loss by eliminating multiple transfers. Color-coded caps allow easy identification of 0.2 μm or 0.45 μm membranes in PVDF, PTFE, PES, or nylon. Preslit PTFE/silicone caps help eliminate broken autosampler needles and cored septa.

Whatman Mini-UniPrep Syringeless Filters | Cytiva

All-in-one filtration device for quick and cost-effective chromatography sample processing Eliminates the need for separate syringes, syringe membrane filters, vials, and septa Designed for use with an UHPLC or HPLC autosampler for high-throughput analysis 0.2 µm and 0.45 µm filter pore sizes available to meet filtration sample requirements

www.autosamplerhplc.com

Thomson SINGLE StEP Standard Filter Vials Easy-to-use vials offer fast sample filtration and require only a squeeze of your fingers. Minimize sample loss by eliminating multiple transfers. Color-coded caps allow easy identification of 0.2 μm or 0.45 μm membranes in PVDF, PTFE, PES, or nylon.

Sample Preparation at Restek

Syringe Filters • Current Promotion – 10% increased discount on top of quantity break discounts for all of 2011 • Current line includes – Cellulose, PVDF, Teflon, and Nylon membranes – 13 and 25mm diameter – 0.22 and 0.45 μm porosity • Just released – PES membranes – 4 and 30mm diameters for all membranes

Key Fetures Low Evaporation Filter Vial Part Numbers

Filter Vial. Filtering samples in-vial with a 3-step process (deposit sample & dilute, press plunger to filter, place in HPLC). Even with a seemingly homogenous sample, filtering with a Thomson Filter Vial is fast and eliminates HPLC downtime. Low Evaporation Cap Filter Vials are available in all four membranes PTFE, PVDF, PES & Nylon and

Sample Preparation

Thomson Filter Vials No multiple step transfers needed. Pre-slit caps for all filter vials, with the exception of the low evaporation caps, ensure a no-hassle, clean aliquot withdrawal. No more breakage of expensive needles or coring problems on the HPLC or Mass Spectrometer. Thomson Filter Vials are compatible with most standard autosamplers.

Rapid Hydrolysis of Benzodiazepines in Urine

Chromatography Systems). Thomson eXtreme|FV® 0.2µm PVDF with pre-slit red caps and a 48 position vial filter press were purchased from Thomson Instrument Company. HPLC grade methanol was purchased from Aijiren Tech Scientific. The 1 mg/mL or 100 µg/mL (Zolpidem) drug solutions used to make the working standards were purchased from Cerilliant

Adsorption Behavior of a Surfactant and a Monoclonal Antibody

The present study investigates filtration forces of monoclonal antibody formulations in a small-scale set-up using polyvinylidene difluoride (PVDF) or polyethersulfone (PES) filters.

Restek | Chromatographic Specialties Inc.

Filter Vials, 0.45um PTFE w/pre-slit cap, Thomson SINGLE StEP, Blue Cap: 100-- Add to Cart: RK25895 Filter Vials, 0.2um PVDF w/pre-slit cap, Thomson SINGLE StEP, Red Cap: 100-- Add to Cart: RK25896 Filter Vials, 0.45um PVDF w/pre-slit cap, Thomson SINGLE StEP, Yellow Cap: 100

Hplc Vials at Thomas Scientific

vial, filtration membrane, plunger, and cap/septa into one consumable product. They are built for fast and easy HPLC/UHPLC sample preparation. All-in-one filtration device for quick and cost-effective sample processing Eliminates the need for separate syringes, syringe membrane filters, vials,

Syringeless Filters | VWR

Learn more about Syringeless Filters. We enable science by offering product choice, services, process excellence and our people make it happen.

Thomson SINGLE StEP Standard Filter Vials, Restek | VWR

Recommended for samples containing less than 10% solid particulates, these standard filter vials are constructed using PTFE or PES for long-lasting durability. Minimize sample loss by eliminating multiple transfers. Color-coded caps allow easy identification of 0.2 μm or 0.45 μm membranes in PVDF, PTFE, PES, or nylon.

Sterilization performance comparison between an autosampler

Jul 26, 2019 · Olympus syringe filters (13 mm, 0.22 micron polyethersulfone (PES)) were from Genesee Scientific (San Diego, CA). Standard and eXtreme/FV® autosampler filter vials (0.2 micron polyvinylidene difluoride (PVDF)) were from Thomson Scientific Instruments (Oceanside, CA).