Single use vial containing 1 gram of functional recommended to use a 5 micron in-line filter (not supplied). 5. Administer intravenously to the patient as described in section 2.3.
Separa® Filter Vial is a one-step sample preparation device consists of an internal insert with a membrane chamber and precut septa cap and an external vial. Separa® Toggler 120 is the multi compressor for simultaneous use up to 12 Separa®. Go back to the global website Select a country or territory to show the localized content: Continue
Dec 1, 2021 · 40 mg Act-O-Vial System (Single-Dose Vial) —Each mL (when mixed) contains methylprednisolone sodium succinate equivalent to 40 mg methylprednisolone; also 1.6 mg monobasic sodium phosphate anhydrous; 17.46 mg dibasic sodium phosphate dried; and 25 mg lactose hydrous.
Instructions for Use . HEMLIBRA® (hem-lee-bruh) (emicizumab-kxwh) injection, for subcutaneous use. Transfer Needle with Filter (For transfer of HEMLIBRA from vial to syringe) Be sure that you read, understand, and follow this Instructions for Use before injecting HEMLIBRA.
Insert the syringe needle into the vial through the center of the rubber stopper and direct the stream of Sterile Water for Injection, USP, to the glass wall of the vial. Gently swirl the solution by rotating the vial to dissolve the lyophilized powder, which has a cake-like appearance. Avoid prolonged or vigorous agitation. DO NOT SHAKE.
Insert the syringe needle into the vial through the center of the rubber stopper and direct the stream of Sterile Water for Injection, USP, to the glass wall of the vial. Gently swirl the solution by rotating the vial to dissolve the lyophilized powder, which has a cake-like appearance. Avoid prolonged or vigorous agitation. DO NOT SHAKE.
Blood collection and sample preparation steps 1. Use an EDTA tube that can be secured in the adapter (13 mm x 75 mm, 1.3 mL, 650 μL). 2. Use a syringe or vacuum collection system. 3. Draw the sample and transfer, if necessary. 4. Invert the tube to mix . Complement your in-house hematology with a high-quality blood film Learn more about blood films
DIRECTIONS FOR USING THE ACT-O-VIAL SYSTEM Press down on plastic activator to force diluent into the lower compartment. Gently agitate to effect solution. Remove plastic tab covering center of stopper. Sterilize top of stopper with a suitable germicide. Insert needle squarely through center of stopper until tip is just visible.
Closed System Transfer Device (CSTD) Health care worker safety is as important as patient safety. OnGuard® CSTD protects employees against the harmful risks of hazardous drug exposure. With more than 500 customers, OnGuard is the market leader in CSTD air-cleaning technology, a NIOSH-recognized hazardous drug containment technology.
INFUSION ADMINISTRATION INSTRUCTIONS. SIMPONI ARIA solution for IV infusion should be diluted by a healthcare professional using aseptic technique as follows: 1. Calculate. Calculate the dosage and the number of SIMPONI ARIA vials needed based on the recommended dosage of 2 mg/kg and the patient’s weight.
Simply, dispense your sample into the external vial and compress the internal plunger to filter. This produces a particulate-free sample ready for analysis. Verex Filter Vials are a standard 12 x 32 mm vial and can be easily loaded into the autosampler. All-in-one sample prep solution. Combines sample storage, transfer, and filtration.
Feb 24, 2023 · Dilution instructions. VYEPTI requires dilution prior to administration. Use appropriate aseptic technique when preparing VYEPTI solution for intravenous (IV) infusion. VYEPTI 100 mg dose: Withdraw 1 mL of VYEPTI from a single-dose vial using a sterile needle and syringe. Inject the 1 mL content into a 100 mL bag of 0.9% Sodium Chloride Injection, USP.
EquaShield Procedures Manual - hhvna.com
Syringe filters and other devices All in one filters and filter vials Integrated devices include the collection receptacle to save time, reduce waste and reduce sample handling.
Mannitol Injection may be autoclaved at 121°C for 20 minutes at 15 psi. Cool to body temperature or less before administering. Re-inspect Mannitol Injection for crystals prior to administration. Discard the solution if all the crystals cannot be dissolved. Remove cover from fliptop vial and cleanse stopper with antiseptic before use.