Available in 0.5mL and 5.0mL sizes, Aijiren Tech™ Dionex™ AS-DV Autosampler PolyVials are supplied in packs of 250, with and without plain or filter caps. Choose from compatible vial holders, adapters and a vial cap removal tool to complete your setup for the AS-DV Autosampler. Product Overview Recommendations Documents
Thomson SINGLE StEP eXtreme Filter Vials. Provide multilayer filtration for viscous samples and samples containing up to 30% solid particulates. Allow compounds to be separated from matrix, resulting in both higher signal-to-noise ratios and more differentiated peaks. Easy-to-use vials offer fast sample filtration and require only a squeeze of
Captiva filter vials remove particulates from your sample and are ideal for simple mechanical filtration. Filtering samples before analysis can extend column lifetime, decrease instrument downtime, and improve sample integrity. Captiva filter vials reduce the steps in your gas chromatography (GC) or high-performance liquid chromatography (HPLC) workflow.
Supplier: Thomson Instrument Thomson nano|Filter Vials offer a low dead volume, allowing filtration with as little as 10 µl of sample with enough remaining filtrate to make a 2 µl injection. In vial filtration with minimal sample loss, 10 µl sample for a 2 µl injection Minimize sample loss by eliminating multiple transfers
Chromatography sample preparation steps involving multiple consumables like syringe filters, vials, and septa increases costs and time required for sample preparation. Whatman Mini-UniPrep syringeless filters eliminate the need for these separate disposable components and prepare samples in one-third the time required by other methods used for high performance liquid chromatography.
Similar to how a french press (cafetière à piston) works, Filter Vials filter particulates out of the sample with similar membranes used in syringe filters. The pressing of the plunger into the shell vial forces the sample up through a filter to separate the particulates from the sample to be analyzed. Thomson has several filter membranes and pore sizes to choose from making the Filter Vial a versatile tool in the lab.
Easy-to-use vials offer fast sample filtration and require only a squeeze of your fingers. Minimize sample loss by eliminating multiple transfers. Color-coded caps allow easy identification of 0.2 μm or 0.45 μm membranes in PVDF, PTFE, PES, or nylon. Preslit PTFE/silicone caps help eliminate broken autosampler needles and cored septa.
Whatman™ Mini-Uniprep™ Syringeless Filters. Cytiva. One-step sample preparation in one-third the time Reduces cost while increasing productivity 0.2 or 0.45 µm filter 12 x 32 mm vials Replace syringe-coupled filtration devices and autosampler vials with a single, disposable unit Available in seven different membrane.
The Stericup™ vacuum filtration system is the most efficient single-use, disposable Bottle Top Filter process for sterile media preparation. It combines a Steritop™ filter unit with a receiver flask for processing and storing volumes from 150 mL to 1000 mL in a single, ready-to-use format. Promotions are available 3
Ultra-low dead volume allows you to filter as little as 10 μL of sample and still obtain enough filtrate to make a 2 μL injection. Easy-to-use vials offer fast sample filtration and require only a squeeze of your fingers. Color-coded caps allow easy identification of 0.2 μm or 0.45 μm membranes in PVDF, PTFE, PES, or nylon.
Hold-up volume provides space in bottom of vial, portion of sample is not filtered. Various filter material and pore sizes available. Vial Size: 12mm x 32mm; Sample Volume Size: <450μL; Closure Type: 11mm Yellow Snap Cap; Septa: Red PTFE/White Silicone with slit
Separa® Filter Vials and Accessories. Separa® Filter Vials and Accessories. Save time and money in the sample preparation process with the GVS Separa® Filter Vial. Separa® is a one-step sample preparation device that allows a quick, effective, and simple to use process integrating a self-sampling system, membrane, cap, and lid with precut septa. The liquid is placed in the outer vial and dispensed by pressing the inner insert so that it is pushed through the membrane.
Hold-up volume provides space in bottom of vial, portion of sample is not filtered. Various filter material and pore sizes available. Vial Size: 12mm x 32mm; Sample Volume Size: <450μL; Closure Type: 11mm Yellow Snap Cap; Septa: Red PTFE/White Silicone with slit
Volume of 0.9% NaClf Total volume (dose) Minimum infusion time (hr) Maximum infusion time (mL/hr) 5 to <10 6 mL (2 vials) + 6 mL = 12 mL (600 mg) 1.4 8 10 to <20 6 mL (2 vials) + 6 mL = 12 mL (600 mg) 0.8 16 20 to <30 9 mL (3 vials) + 9 mL = 18 mL (900 mg) 0.6 30 30 to <40 12 mL (4 vials) + 12 mL = 24 mL ( mg) 0.5 46 40 to <60 24 mL (8 vials)
volume with decreased hand pressure. Mini-UniPrep and Mini-UniPrep G2 simplify and speed up HPLC/UHPLC sample preparation by eliminating multiple consumables. These devices act both as filters and autosampler vials. Puradisc syringe filters provide quick, efficient filtration of samples up to 100 ml. The availability of a wide range